lightrush

joined 2 years ago
MODERATOR OF
[–] lightrush@lemmy.ca 8 points 1 month ago

Reaches 125 on the balcony.

[–] lightrush@lemmy.ca 11 points 1 month ago

And long term economic planning, and therefore public investment in science.

[–] lightrush@lemmy.ca 4 points 1 month ago (1 children)

China’s biotech industry has evolved to the point that U.S. and European pharmaceutical giants in the last several months have spent billions to acquire China-developed drugs that could treat cancer if commercialized with regulatory approval. In March, British pharmaceutical giant AstraZeneca announced it will invest $2.5 billion in a research and development center in Beijing.

In case you thought research isn't subject to outsourcing.

[–] lightrush@lemmy.ca 2 points 3 months ago

There's a different line for the poor.

[–] lightrush@lemmy.ca 10 points 3 months ago

BTW, just in case you want a different domain, not saying you do, but I gave feddit.ca to the admins a couple of years ago. 😊

[–] lightrush@lemmy.ca 0 points 3 months ago (1 children)

You should read about what happened to domestic left parties and people after WWII. Also what the US did to left elements abroad. The state of the left in the US today didn't evolve naturally to its current status quo.

[–] lightrush@lemmy.ca 5 points 5 months ago

That's literally the program which benefits their donors.

[–] lightrush@lemmy.ca 1 points 5 months ago* (last edited 5 months ago)

Retried just now on pixelfed.ca and it worked fine. 🙏

Here's a bike for you.

[–] lightrush@lemmy.ca 2 points 5 months ago* (last edited 5 months ago) (2 children)

Can't sign up through the web app. The web form sends the request, then the password fields clear, then nothing. Just stays there.

[–] lightrush@lemmy.ca 3 points 5 months ago

#FordNation special

[–] lightrush@lemmy.ca 8 points 5 months ago

It's the best kept web dev secret.

[–] lightrush@lemmy.ca 3 points 5 months ago

Seems to work!

 

There's still time to catch it if you're around.

If you want to catch the next one, head to their page and keep an eye.

 

cross-posted from: https://lemmy.ca/post/31824976

Lately I've had some obviously inaccurate measurements from my Timemore Black Mirror scale. That would happen occasionally but not always. I was charging it today and as luck would have it, I was sitting beside it. I typically charge it unattended. I noticed that it took a very long time to charge and multiple times it seemed to restart charging. I grabbed it to check the cable and noticed it was quite warm in one spot. I though - that's alright, it's likely where the battery cell is, it's charging, lithium cells get warm during charging. Later I took it off the charger and while handling it I examined the hot spot a bit more. I noticed that when I squeezed the scale at that corner, the top plate wouldn't sink towards the bottom as it does in the other corners. A few mental calculations later I figured this could be a swollen cell that has grown so large that it impacts the plates and doesn't let them come together as they do normally. I took it apart. Lo and behold this spicy pillow:

The marking on it means it's supposed to be 8mm thick. It's currently closer to 12.5mm. Removing the battery allowed the two plates to come together in all corners as normal. That confirmed the hypothesis. Further, the reason why it only occasionally impacted the measurements is likely due to the weight of the cup I was using. When using a lighter cup, the total weight would be lower than needed to get the two plate to touch the battery and produce inaccurate measurement.

I ordered this as a replacement. It fits the dimensions and it's got some safety certification.

To check if your scale is a fire hazard, squeeze this corner:

Normal squeeze action looks like this. Unfortunately I didn't record a video prior to removing the battery.

If it the two plates come together as the do in the other corners, you're probably okay. If the plates don't come nearly as close, you've got an unlit petard in your hands.

 

cross-posted from: https://lemmy.ca/post/31824976

Lately I've had some obviously inaccurate measurements from my Timemore Black Mirror scale. That would happen occasionally but not always. I was charging it today and as luck would have it, I was sitting beside it. I typically charge it unattended. I noticed that it took a very long time to charge and multiple times it seemed to restart charging. I grabbed it to check the cable and noticed it was quite warm in one spot. I though - that's alright, it's likely where the battery cell is, it's charging, lithium cells get warm during charging. Later I took it off the charger and while handling it I examined the hot spot a bit more. I noticed that when I squeezed the scale at that corner, the top plate wouldn't sink towards the bottom as it does in the other corners. A few mental calculations later I figured this could be a swollen cell that has grown so large that it impacts the plates and doesn't let them come together as they do normally. I took it apart. Lo and behold this spicy pillow:

The marking on it means it's supposed to be 8mm thick. It's currently closer to 12.5mm. Removing the battery allowed the two plates to come together in all corners as normal. That confirmed the hypothesis. Further, the reason why it only occasionally impacted the measurements is likely due to the weight of the cup I was using. When using a lighter cup, the total weight would be lower than needed to get the two plate to touch the battery and produce inaccurate measurement.

I ordered this as a replacement. It fits the dimensions and it's got some safety certification.

To check if your scale is a fire hazard, squeeze this corner:

Normal squeeze action looks like this. Unfortunately I didn't record a video prior to removing the battery.

If it the two plates come together as the do in the other corners, you're probably okay. If the plates don't come nearly as close, you've got an unlit petard in your hands.

 

Lately I've had some obviously inaccurate measurements from my Timemore Black Mirror scale. That would happen occasionally but not always. I was charging it today and as luck would have it, I was sitting beside it. I typically charge it unattended. I noticed that it took a very long time to charge and multiple times it seemed to restart charging. I grabbed it to check the cable and noticed it was quite warm in one spot. I though - that's alright, it's likely where the battery cell is, it's charging, lithium cells get warm during charging. Later I took it off the charger and while handling it I examined the hot spot a bit more. I noticed that when I squeezed the scale at that corner, the top plate wouldn't sink towards the bottom as it does in the other corners. A few mental calculations later I figured this could be a swollen cell that has grown so large that it impacts the plates and doesn't let them come together as they do normally. I took it apart. Lo and behold this spicy pillow:

The marking on it means it's supposed to be 8mm thick. It's currently closer to 12.5mm. Removing the battery allowed the two plates to come together in all corners as normal. That confirmed the hypothesis. Further, the reason why it only occasionally impacted the measurements is likely due to the weight of the cup I was using. When using a lighter cup, the total weight would be lower than needed to get the two plate to touch the battery and produce inaccurate measurement.

I ordered this as a replacement. It fits the dimensions and it's got some safety certification.

To check if your scale is a fire hazard, squeeze this corner:

Normal squeeze action looks like this. Unfortunately I didn't record a video prior to removing the battery.

If it the two plates come together as the do in the other corners, you're probably okay. If the plates don't come nearly as close, you've got an unlit petard in your hands.

 

cross-posted from: https://lemmy.ca/post/30850573

 

41
Donglecast (infosec.pub)
submitted 9 months ago* (last edited 9 months ago) by lightrush@lemmy.ca to c/androidmemes@lemdro.id
 

cross-posted from: https://lemmy.ca/post/30593626

#donglelife

Apparently this isn't allowed in !Android and should go here instead.

A Chromecast with Google TV connected to a USB-C hub, connected to an Ethernet dongle, connected to an HDMI coupler.

 
27
submitted 10 months ago* (last edited 10 months ago) by lightrush@lemmy.ca to c/coffee@lemmy.world
 

I'm syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat and I noticed that one of the disks consistently shows less than half the write IOPS of the other:

                                        capacity     operations     bandwidth 
pool                                  alloc   free   read  write   read  write
------------------------------------  -----  -----  -----  -----  -----  -----
storage-volume-backup                 5.03T  11.3T      0    867      0   330M
  mirror-0                            5.03T  11.3T      0    867      0   330M
    wwn-0x5000c500e8736faf                -      -      0    212      0   164M
    wwn-0x5000c500e8737337                -      -      0    654      0   165M

This is also evident in iostat:

     f/s f_await  aqu-sz  %util Device
    0.00    0.00    3.48  46.2% sda
    0.00    0.00    8.10  99.7% sdb

The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.

Is this behaviour expected?

 

UofT is closing the [first.last]@mail.utoronto.ca email accounts for alumni. You can get a new email account that will end in @alumni.utoronto.ca but this won't happen automatically. You have to request one. Check your current UTmail+ inbox for an email titled "Notice of Upcoming Email Account Closure"

view more: ‹ prev next ›