The original post: /r/datahoarder by /u/Matticus54r on 2024-07-06 01:43:54.

I bought a Manufacture Recertified Wester Digital 18tb from Server Parts Deal. Straight out of the box it has 30001 Pending Defects log.

What do you all think?

smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.1.74-Unraid] (local build)

Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===

Model Family: Western Digital Ultrastar DC HC550

Device Model: WDC WUH721818ALE6L4

Serial Number: 3GHSGT6E

LU WWN Device Id: 5 000cca 2afd8c386

Firmware Version: PCGNW870

User Capacity: 18,000,207,937,536 bytes [18.0 TB]

Sector Sizes: 512 bytes logical, 4096 bytes physical

Rotation Rate: 7200 rpm

Form Factor: 3.5 inches

Device is: In smartctl database 7.3/5577

ATA Version is: ACS-4 published, ANSI INCITS 529-2018

SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)

Local Time is: Thu Jul 4 19:19:47 2024 CDT

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

AAM feature is: Unavailable

APM feature is: Disabled

Rd look-ahead is: Enabled

Write cache is: Enabled

DSN feature is: Unavailable

ATA Security is: Disabled, frozen [SEC2]

Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

General SMART Values:

Offline data collection status: (0x80) Offline data collection activity

was never started.

Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever

been run.

Total time to complete Offline

data collection: ( 101) seconds.

Offline data collection

capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

No Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine

recommended polling time: ( 2) minutes.

Extended self-test routine

recommended polling time: (1903) minutes.

SCT capabilities: (0x003d) SCT Status supported.

SCT Error Recovery Control supported.

SCT Feature Control supported.

SCT Data Table supported.

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE

1 Raw_Read_Error_Rate PO-R-- 100 100 001 - 0

2 Throughput_Performance P-S--- 100 100 054 - 0

3 Spin_Up_Time POS--- 099 099 001 - 67

4 Start_Stop_Count -O--C- 100 100 000 - 1

5 Reallocated_Sector_Ct PO--CK 100 100 001 - 0

7 Seek_Error_Rate PO-R-- 100 100 001 - 0

8 Seek_Time_Performance P-S--- 100 100 020 - 0

9 Power_On_Hours -O--C- 100 100 000 - 1

10 Spin_Retry_Count PO--C- 100 100 001 - 0

12 Power_Cycle_Count -O--CK 100 100 000 - 1

22 Helium_Level PO---K 100 100 025 - 6553700

192 Power-Off_Retract_Count -O--CK 100 100 000 - 1

193 Load_Cycle_Count -O--C- 100 100 000 - 1

194 Temperature_Celsius -O---- 053 053 000 - 40 (Min/Max 24/40)

196 Reallocated_Event_Count -O--CK 100 100 000 - 0

197 Current_Pending_Sector -O---K 100 100 000 - 0

198 Offline_Uncorrectable ---R-- 100 100 000 - 0

199 UDMA_CRC_Error_Count -O-R-- 100 100 000 - 0

||||||_ K auto-keep

|||||__ C event count

||||___ R error rate

|||____ S speed/performance

||_____ O updated online

|______ P prefailure warning

General Purpose Log Directory Version 1

SMART Log Directory Version 1 [multi-sector log support]

Address Access R/W Size Description

0x00 GPL,SL R/O 1 Log Directory

0x01 SL R/O 1 Summary SMART error log

0x02 SL R/O 1 Comprehensive SMART error log

0x03 GPL R/O 1 Ext. Comprehensive SMART error log

0x04 GPL R/O 256 Device Statistics log

0x04 SL R/O 255 Device Statistics log

0x06 SL R/O 1 SMART self-test log

0x07 GPL R/O 1 Extended self-test log

0x08 GPL R/O 2 Power Conditions log

0x09 SL R/W 1 Selective self-test log

0x0c GPL R/O 30001 Pending Defects log

0x10 GPL R/O 1 NCQ Command Error log

0x11 GPL R/O 1 SATA Phy Event Counters log

0x12 GPL R/O 1 SATA NCQ Non-Data log

0x13 GPL R/O 1 SATA NCQ Send and Receive log

0x15 GPL R/W 1 Rebuild Assist log

0x21 GPL R/O 1 Write stream error log

0x22 GPL R/O 1 Read stream error log

0x24 GPL R/O 256 Current Device Internal Status Data log

0x25 GPL R/O 256 Saved Device Internal Status Data log

0x2f GPL R/O 1 Set Sector Configuration

0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log

0x80-0x9f GPL,SL R/W 16 Host vendor specific log

0xa6 GPL VS 192 Device vendor specific log

0xb7 SL VS 1 Device vendor specific log

0xd8 GPL,SL VS 1 Device vendor specific log

0xe0 GPL,SL R/W 1 SCT Command/Status

0xe1 GPL,SL R/W 1 SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)

No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)

Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error

1 Short offline Completed without error 00% 1 -

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing

2 0 0 Not_testing

3 0 0 Not_testing

4 0 0 Not_testing

5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version: 3

SCT Version (vendor specific): 256 (0x0100)

Device State: Active (0)

Current Temperature: 40 Celsius

Power Cycle Min/Max Temperature: 24/40 Celsius

Lifetime Min/Max Temperature: 24/40 Celsius

Under/Over Temperature Limit Count: 0/0

SMART Status: 0xc24f (PASSED)

Minimum supported ERC Time Limit: 65 (6.5 seconds)

SCT Temperature History Version: 2

Temperature Sampling Period: 1 minute

Temperature Logging Interval: 1 minute

Min/Max recommended Temperature: 0/60 Celsius

Min/Max Temperature Limit: -40/70 Celsius

Temperature History Size (Index): 128 (62)

Index Estimated Time Temperature Celsius

63 2024-07-04 17:12 0 -

... ..( 63 skipped). .. -

127 2024-07-04 18:16 0 -

0 2024-07-04 18:17 25 ******

1 2024-07-04 18:18 26 *******

2 2024-07-04 18:19 26 *******

3 2024-07-04 18:20 26 *******

4 2024-07-04 18:21 27 ********

5 2024-07-04 18:22 27 ********

6 2024-07-04 18:23 28 *********

7 2024-07-04 18:24 28 *********

8 2024-07-04 18:25 29 **********

9 2024-07-04 18:26 29 **********

10 2024-07-04 18:27 30 ***********

11 2024-07-04 18:28 30 ***********

12 2024-07-04 18:29 31 ************

13 2024-07-04 18:30 31 ************

14 2024-07-04 18:31 31 ************

15 2024-07-04 18:32 32 *************

16 2024-07-04 18:33 32 *************

17 2024-07-04 18:34 32 *************

18 2024-07-04 18:35 33 **************

19 2024-07-04 18:36 33 **************

20 2024-07-04 18:37 33 **************

21 2024-07-04 18:38 34 ***************

... ..( 2 skipped). .. ***************

24 2024-07-04 18:41 34 ***************

25 2024-07-04 18:42 35 ****************

... ..( 2 skipped). .. ****************

28 2024-07-04 18:45 35 ****************

29 2024-07-04 18:46 36 *****************

... ..( 3 skipped). .. *****************

33 2024-07-04 18:50 36 *****************

34 2024-07-04 18:51 37 ******************

... ..( 3 skipped). .. ******************

38 2024-07-04 18:55 37 ******************

39 2024-07-04 18:56 38 *******************

... ..( 5 skipped). .. *******************

45 2024-07-04 19:02 38 *******************

46 2024-07-04 19:03 39 ********************

... ..( 7 skipped). .. ********************

54 2024-07-04 19:11 39 ********************

55 2024-07-04 19:12 40 *********************

... ..( 5 skipped). .. *********************

61 2024-07-04 19:18 40 *********************

62 2024-07-04 19:19 0 -

SCT Error Recovery Control:

Read: Disabled

Write: Disabled

Device Statistics (GP Log 0x04)

Page Offset Size Value Flags Description

0x01 ===== = = === == General Statistics (rev 1) ==

0x01 0x008 4 1


Lifetime Power-On Resets

0x01 0x010 4 1


Power-on Hours

0x01 0x018 6 239215656


Logical Sectors Written

0x01 0x020 6 1545767


Number of Write Commands

0x01 0x028 6 6346


Logical Sectors Read

0x01 0x030 6 154


Number of Read Commands

0x01 0x038 6 3677550


Date and Time TimeStamp

0x03 ===== = = === == Rotating Media Statistics (rev 1) ==

0x03 0x008 4 1


Spindle Motor Power-on Hours

0x03 0x010 4 1


Head Flying Hours

0x03 0x018 4 1


Head Load Events

0x03 0x020 4 0


Number of Reallocated Logical Sectors

0x03 0x028 4 0


Read Recovery Attempts

0x03 0x030 4 0


Number of Mechanical Start ...


Content cut off. Read original on https://old.reddit.com/r/DataHoarder/comments/1dwech0/server_parts_deallots_of_pending_defects_log/

no comments (yet)
sorted by: hot top controversial new old
there doesn't seem to be anything here