this post was submitted on 04 Nov 2025
79 points (100.0% liked)

Ask Lemmy

35387 readers
1309 users here now

A Fediverse community for open-ended, thought provoking questions


Rules: (interactive)


1) Be nice and; have funDoxxing, trolling, sealioning, racism, and toxicity are not welcomed in AskLemmy. Remember what your mother said: if you can't say something nice, don't say anything at all. In addition, the site-wide Lemmy.world terms of service also apply here. Please familiarize yourself with them


2) All posts must end with a '?'This is sort of like Jeopardy. Please phrase all post titles in the form of a proper question ending with ?


3) No spamPlease do not flood the community with nonsense. Actual suspected spammers will be banned on site. No astroturfing.


4) NSFW is okay, within reasonJust remember to tag posts with either a content warning or a [NSFW] tag. Overtly sexual posts are not allowed, please direct them to either !asklemmyafterdark@lemmy.world or !asklemmynsfw@lemmynsfw.com. NSFW comments should be restricted to posts tagged [NSFW].


5) This is not a support community.
It is not a place for 'how do I?', type questions. If you have any questions regarding the site itself or would like to report a community, please direct them to Lemmy.world Support or email info@lemmy.world. For other questions check our partnered communities list, or use the search function.


6) No US Politics.
Please don't post about current US Politics. If you need to do this, try !politicaldiscussion@lemmy.world or !askusa@discuss.online


Reminder: The terms of service apply here too.

Partnered Communities:

Tech Support

No Stupid Questions

You Should Know

Reddit

Jokes

Ask Ouija


Logo design credit goes to: tubbadu


founded 2 years ago
MODERATORS
 

Personally I love oranges but cant stand orange juice.

you are viewing a single comment's thread
view the rest of the comments
[–] neidu3@sh.itjust.works 18 points 15 hours ago* (last edited 15 hours ago) (5 children)

People rip on US electricity standards all the time, from voltage, via frequency, to the NEMA plugs, and for good reasons. But the most disgusting thing about it all is this:

US breaker panels are fugly. Sure, they work just as well as those from the rest of the world, but they're aesthetically displeasing.

Two representative pictures I found of an average panel just now;

US:

EU:

Thank you for coming to my TED talk.

[–] quediuspayu@lemmy.dbzer0.com 1 points 7 hours ago (1 children)

Why is everything sideways in the American one? From the numbers on the switches to the warning labels.

[–] dondelelcaro@lemmy.world 3 points 7 hours ago (1 children)

It's done that way so the breaker box will fit between studs that are 18" on center, which is standard for USA residential construction.

You generally only see breakers on din rail in the USA in industrial equipment.

[–] quediuspayu@lemmy.dbzer0.com 1 points 7 hours ago

That makes sense.

[–] railway692@piefed.zip 12 points 14 hours ago

This is the kind of unimportant but fascinating thing I wish we had a community for.

Just... hundreds of people around the world posting their breaker panels.

[–] owenfromcanada@lemmy.ca 4 points 13 hours ago

Wait, does that EU panel have extra space for labels? That is sexy and now I'm jealous.

[–] owenfromcanada@lemmy.ca 7 points 15 hours ago (1 children)

Wait... what do they look like elsewhere? They're the same where I am in Canada...

[–] Truscape@lemmy.blahaj.zone 7 points 15 hours ago

US and Canada largely have the same power generation/delivery standards.

[–] fullsquare@awful.systems 3 points 14 hours ago (2 children)

wait, how do you route cables in there? is there just a massive bundle right through the middle?

[–] Fetus@lemmy.world 5 points 14 hours ago* (last edited 14 hours ago)

I'm Australian, but some of the older switchboards in industrial installations are similar in appearance to the top image.

The middle would have a busbar (or three if it's a three phase panel) that connects the circuit breakers to the main switch. The cables are connected to the far left and far right sides of the breakers.

It could be different in the US, though, if anyone with more relevant experience wants to chime in.

Edit: looking back at the top image, I'm reminded that the US uses split phase in some places, so that top panel likely has two busbars down the middle.

[–] neidu3@sh.itjust.works 4 points 14 hours ago* (last edited 14 hours ago) (1 children)

Varies with installation type, age, and scale, but one common approach is to daisy chain the breakers via rails that carry each phase. I couldn't find a good picture, but basically the rails and breakers are standardized so that a row of breakers will line up with the-rail terminals, so when you connect the rail to the mains you're good to go. On the output of the breaker it's common to use cable ducts to keep everything nice and tidy.

EDIT: Found a picture:

[–] fullsquare@awful.systems 1 points 14 hours ago* (last edited 14 hours ago) (1 children)

american version would probably only have two phases at best, and possibly just one

[–] halcyoncmdr@lemmy.world 3 points 12 hours ago (1 children)

Every building receives 240V and splits it into a pair of 120V phases. Three phase power is basically only installed at large industrial sites or very specialized shops.

[–] fullsquare@awful.systems 1 points 11 hours ago* (last edited 11 hours ago)

here if you need anything over certain power (6kW; depends on country i guess) you need a three phase installation, and even if you get single phase, it's really handled as three phase split between single phase customers (a block gets three phase supply, then splits flats in three groups, each group gets connected to one phase). this gets supplied by a distribution transformer that might serve somewhere around 200 people per (in residential areas)

i understand that sometimes americans also get distribution like this, with 208/120 three phase coming from substation, without 240v available