this post was submitted on 04 Aug 2025
99 points (99.0% liked)

Ukraine

10497 readers
617 users here now

News and discussion related to Ukraine

Matrix Space


Community Rules

🇺🇦 Sympathy for enemy combatants is prohibited.

🌻🤢No content depicting extreme violence or gore.

💥Posts containing combat footage should include [Combat] in title

🚷Combat videos containing any footage of a visible human involved must be flagged NSFW

❗ Server Rules

  1. Remember the human! (no harassment, threats, etc.)
  2. No racism or other discrimination
  3. No Nazis, QAnon or similar
  4. No porn
  5. No ads or spam (includes charities)
  6. No content against Finnish law

💳 Defense Aid 💥


💳 Humanitarian Aid ⚕️⛑️


🪖 Volunteer with the International Legionnaires


See also:

!nafo@lemm.ee

!combatvideos@SJW


founded 3 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] shadowtofu@discuss.tchncs.de 1 points 1 day ago (5 children)

I would assume/hope that it’s pretty simple to collect all the cables again? Just “walk” once across the field, pick up all the cables, roll them up, and you are done? I am kind of wondering why the operator couldn’t just roll up the cable from their side again after the end of the flight. But I can understand that that is not a priority at that point.

[–] Kazumara@discuss.tchncs.de 11 points 1 day ago (3 children)

There is no way these bare fibers have the tensile strength necessary that you even could drag kilometers of it back to the operator through the terrain. You need to know, these are not full cables as you would normally use them for networking, that would be to heavy for the drone. Instead it's single fiber strands without any mantle.

[–] nailbar@sopuli.xyz 2 points 12 hours ago (2 children)

They're surprisingly durable. Afaik you can't break them with your bare hands, you need something to cut them with.

[–] Kazumara@discuss.tchncs.de 3 points 12 hours ago

Well I have never tried to deliberately break a fiber, usually my goal is to have them work when I'm done. But the bare fibers without mantle are really thin (250 micrometer is typical, 125 for core and cladding, and 125 around that for the coating) and you have to treat them carefully. I think if you bent them tight they would break. I know splicing tools have special cutters included, but my understanding was that those are only needed to make a proper 90° cut good for splicing.

load more comments (1 replies)
load more comments (1 replies)
load more comments (2 replies)