Ignoring scale and any local requirements, yes, that's a valid trap and vent.

Be aware that local inspectors can be touchy about t-junctions. You might need a rounded or angled junction here so the new drain doesn't splash directly against the opposite side of the vent.

[–] ccunning@lemmy.world 7 points 7 months ago (2 children)

Cool - thank you…

Do you happen to know why so many diagrams seem to have loops? (like this):

[–] DemBoSain@midwest.social 9 points 7 months ago

Without that extra loop, it's possible that flushing the toilet will suck the water out of your sink trap.